/ NOTES
NOTES
1 4.2 x 2 x 1,2 cm 2 3 4 Voltage Divider 5 6 up to 17V 7 8 4990R : 340R 9 10 11 Voltage Calibration 12 13 Provide exactly 16.8V 14 adjust VCC to 5.1V without load 15 Reset, wait until output led turns green 16 17 Current calibration 18 19 connect VSENSE to GND 20 add max short time load resistor between output 21 Reset, wait until output led turns red again 22 add max continous time load resistor between output, within 2 minutes 23 output led will first turn green, measuring load, then turn red again 24 done, reconnect VSENSE 25 26 27 28 Current limiting: 29 30 Peak: 31 Maximim Peak current 32 Compile time Option, defaults to 1.5 times short time level 33 34 Short Time 35 Timing: compile time option, approx 10 Sec default 36 37 Continous 38 Integrates over approx 1 minute 39 40 41 42 43 44 45 46